HOW to READ CATALOGUE CARDS
Distance for mounting elements
Product weight
Direct website address with complete technical information regarding the product
Dispatch terms for standard execution
CONNECTION HEAD - type XE-DANAW http://www.limatherm.com/en/xe–danaw Keep cover tight when circuits alive
Kg
B
B-B
~0.30 Kg
d1 D1
Designation of fundamental parts of product. For more detalils see pages 6 to 7
EX HEADS
Technical specification page 219 - 233
06
ORDERING CODE
(1) XE-DANAW
(3)
(5)
Material of elements
M2 N2
Type of process thread D1/d1
(7)
Cover closure
(8)
Paint type
M20x1.5 ½NPT (empty thread only) d1 [ø] D1[ø] 5 6 7 8 9 10 NS LS P E C SE SPU al yc ys
Following parts of ordering code. Correct code should include all elements, from product name to paint colour
(9)
Paint colour
bs sb sg gr ag sh gs cw
70
M24x1.5 Ø14 G⅜ Ø11 G½ Ø11 G¾ Ø14 ½NPT Ø17.35 ¾NPT Ø22.70 Screws without leaden seal holes Screws with leaden seal holes Polyester (~70 μm) Epoxy (~70 μm) Creodur - Ra l (~30 μm) Spray epoxy (~70 μm) Spray polyurethane on (SE) layer (~120 μm) alu natural colour RAL 1007 daffodil yellow RAL 1003 signal yellow RAL 5005 signal blue RAL 5015 sky blue RAL 7032 pebble grey RAL 7035 light grey RAL 9002 grey white RAL 9006 white aluminium RAL 9007 grey aluminium RAL 9010 pure white
A-A 4xM4x8 33
PTN-1.5 Protection terminal ETN-4 Earth Terminal
Maine features:
SPECIFICATION Cable gland - nickel - plated brass; other metal parts stainless steel; seals-oil resistant rubber (-40...100ºC)
3
Cable gland thread
26
A
Flameproof Zone 1, Zone 21 Zone 2, Zone 22
(2)
33
A
l1 17
dwpatch
Protection method and permitted use
NS LS
D2
da y
41.5
2
B Ø83
~114
33
Certificate (if product is certified)
4xM4x5
l1 14 14 14 14 20 20
• material of body and cover - aluminium pressure die-castings, max 0.5%Mg
General information
• cable gland washer - zinc-plated press steel • service temperature: Tserv= -40÷100ºC • maximum space for transmitter: Ø45x16mm, Ø60x40mm PROTECTION DEGREE IP
D2
54 to 66
ATEX EX e cable gland IP66
54 to 68
ATEX EX e cable gland IP68
D1 pos. 5 to 10 pos. 5 to 10
Ordering example: (1) XE-DANAW
(2) (3) (5) (7) (8) (9) 3 - M2 - 5 - NS - P sh
Table of related components that may be used with the main product Example of compete ordering code
www.limathermcomponents.com, e-mail:
[email protected] tel.: +48 32 7831610, +4832 327831601 7831601 e-mail:
[email protected], tel. +48 32 7831610, faxfax: +48
tel.: +48 32 7831610, fax: +48 32 7831601
www.limathermcomponents.com, e-mail:
[email protected]