ELS100-48tx2m.book Page -i Thursday, November 16, 2000 4:59 PM

VERTICAL HORIZON VH-4802 FAST ETHERNET SWITCH USER GUIDE

9033630

ELS100-48tx2m.book Page 0 Thursday, November 16, 2000 4:59 PM

ELS100-48tx2m.book Page i Thursday, November 16, 2000 4:59 PM

Notice

Only qualified personnel should perform installation procedures.

NOTICE Enterasys Networks reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.

 2000 by Enterasys Networks, Inc., P.O. Box 5005, Rochester, NH 03866-5005 All Rights Reserved Printed in Taiwan, R.O.C. Order Number: 9033630 November 2000 Enterasys, Enterasys Networks, and Vertical Horizon are trademarks or registered trademarks of Enterasys Networks, Inc. Microsoft, Windows, Windows 95, Windows 98, and Windows NT are either trademarks or registered trademarks of Microsoft Corporation. Netscape and Netscape Navigator are trademarks of Netscape Communications Corporation. All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.

9033630

i

ELS100-48tx2m.book Page ii Thursday, November 16, 2000 4:59 PM

Notice FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense. WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

VCCI NOTICE This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS The VH-4802 48-port switch uses Class 1 Laser transceivers. Read the following safety information before installing or operating these modules. Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment. Class 1 Laser transceivers comply with the following safety standards:

ii

9033630

ELS100-48tx2m.book Page iii Thursday, November 16, 2000 4:59 PM

Notice • 21 CFR 1040.10 and 1040.11 U.S. Department of Health and Human Services (FDA). • IEC Publication 825 (International Electrotechnical Commission). • CENELEC EN 60825 (European Committee for Electrotechnical Standardization). • When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission limit of all three standards. Class 1 levels of laser radiation are not considered hazardous.

SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS LASER RADIATION AND CONNECTORS When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10-6 watts. Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The maximum radiance from the optical port (under worst case conditions) is 0.8 W cm-2 or 8 x 103 W m2 sr-1. Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the switch.

WARNING: FIBER OPTIC PORT SAFETY When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on.

AVERTISSMENT: PORTS POUR FIBRES OPTIQUES SÉCURITÉ SUR LE PLAN OPTIQUE Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension.

WARNHINWEIS: FASEROPTIKANSCHLÜSSE OPTISCHE SICHERHEIT Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind.

9033630

iii

ELS100-48tx2m.book Page iv Thursday, November 16, 2000 4:59 PM

Notice SAFETY INFORMATION WICHTIGE SICHERHEITSHINWEISE (GERMANY) 1.

Bitte lesen Sie diese Hinweise sorgfältig durch.

2.

Heben Sie diese Anleitung für den späteren Gebrauch auf.

3.

Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung.

4.

Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein.

5.

Das Gerät ist vor Feuchtigkeit zu schützen.

6.

Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten. Ein Kippen oder Fallen könnte Beschädigungen hervorrufen.

7.

Die Belüftungsöffnungen dienen der Luftzirkulation, die das Gerät vor Überhitzung schützt. Sorgen Sie dafür, daß diese Öffnungen nicht abgedeckt werden.

8.

Beachten Sie beim Anschluß an das Stromnetz die Anschlußwerte.

9.

Verlegen Sie die Netzanschlußleitung so, daß niemand darüber fallen kann. Es sollte auch nichts auf der Leitung abgestellt werden.

10.

Alle Hinweise und Warnungen, die sich am Gerät befinden, sind zu beachten.

11.

Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer Überspannung eine Beschädigung vermieden.

12.

Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand bzw. elektrischen Schlag auslösen.

13.

Öffnen sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden.

14.

Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen: a. Netzkabel oder Netzstecker sind beschädigt. b. Flüssigkeit ist in das Gerät eingedrungen. c. Das Gerät war Feuchtigkeit ausgesetzt. d. Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen. e. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt. f. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.

15.

Zum Netzanschluß dieses Gerätes ist eine geprüfte Leitung zu verwenden. Für einen Nennstrom bis 6A und einem Gerätegewicht größer 3kg ist eine Leitung nicht leichter als H05VV-F, 3G, 0.75mm2 einzusetzen.

Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt 70dB(A) oder weniger.

iv

9033630

ELS100-48tx2m.book Page v Thursday, November 16, 2000 4:59 PM

Notice ENTERASYS NETWORKS, INC. PROGRAM LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Enterasys Networks, Inc. (“Enterasys”) that sets forth your rights and obligations with respect to the Enterasys software program (“Program”) in the package. The Program may be contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO ENTERASYS OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND. IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS (603) 332-9400. Attn: Legal Department. 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Enterasys. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts. 4. EXPORT REQUIREMENTS. You understand that Enterasys and its Affiliates are subject to regulation by agencies of the U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain technical products to certain countries, unless a license to export the product is obtained from the U.S. Government or an exception from obtaining such license may be relied upon by the exporting party. If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes. If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, You agree not to (i) reexport or release the Program, the source code for the Program or technology to a national of a country in Country Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova, North Korea, the People’s Republic of China, Romania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct product of the Program or the technology, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a complete plant or any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a major component thereof, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.

9033630

v

ELS100-48tx2m.book Page vi Thursday, November 16, 2000 4:59 PM

Notice 5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was developed solely at private expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Product is considered commercial computer software in accordance with DFARS section 227.7202-3 and its successors, and use, duplication, or disclosure by the Government is subject to restrictions set forth herein. 6. EXCLUSION OF WARRANTY. Except as may be specifically provided by Enterasys in writing, Enterasys makes no warranty, expressed or implied, concerning the Program (including its documentation and media). ENTERASYS DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY ENTERASYS IN WRITING, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE. 7. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL ENTERASYS OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS ENTERASYS PRODUCT, EVEN IF ENTERASYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU.

vi

9033630

ELS100-48tx2m.book Page vii Thursday, November 16, 2000 4:59 PM

Notice DECLARATION OF CONFORMITY Application of Council Directive(s):

Manufacturer’s Name: Manufacturer’s Address:

European Representative Name: European Representative Address:

Conformance to Directive(s)/Product Standards:

Equipment Type/Environment:

89/336/EEC 73/23/EEC Enterasys Networks, Inc. 35 Industrial Way PO Box 5005 Rochester, NH 03867 Mr. J. Sims Enterasys Networks Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG14 2PZ, England EC Directive 89/336/EEC EC Directive 73/23/EEC EN 55022 EN 50082-1 EN 60950 Networking Equipment, for use in a Commercial or Light Industrial Environment.

We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this notice conforms to the above directives. Manufacturer

Legal Representative in Europe

Mr. Thomas Whissel ___________________________________ Full Name

Mr. J. Sims ___________________________________ Full Name

Compliance Engineering Manager ___________________________________ Title

Managing Director - E.M.E.A. ___________________________________ Title

Rochester, NH, USA ___________________________________ Location

Newbury, Berkshire, England ___________________________________

9033630

Location

vii

ELS100-48tx2m.book Page viii Thursday, November 16, 2000 4:59 PM

Notice

viii

9033630

ELS100-48tx2m.book Page ix Thursday, November 16, 2000 4:59 PM

TABLE OF CONTENTS PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XI Purpose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xi Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xi Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xi Message Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xi Keyboard Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xi Other Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii 1. PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Optional Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Feature Summaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 IEEE 802.1D Bridge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Spanning Tree Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Frame Buffering and Frame Latency . . . . . . . . . . . . . . . . . . . . . . . . 7 Software Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Non-Volatile Parameter Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Configuration and Management Interfaces . . . . . . . . . . . . . . . . . . . 8 RMON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Port Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Auto-negotiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 BootP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Full Duplex Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Flow Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Virtual LANs (VLANs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Class of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Port Trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Application Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Client/Server Network Application . . . . . . . . . . . . . . . . . . . . . . . . . 15 Local Backbone Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Inspecting Your Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Mounting the Switch on a Table or Shelf . . . . . . . . . . . . . . . . . . . . . . . 18 Mounting the Switch in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Installing an Optional Module into the Switch . . . . . . . . . . . . . . . . . . . . 20 Connecting a Terminal to the Console Port . . . . . . . . . . . . . . . . . . . . . 21 Console Port (Out-of-Band) Connections . . . . . . . . . . . . . . . . . . . 21 9033630

Table of Contents ix

ELS100-48tx2m.book Page x Thursday, November 16, 2000 4:59 PM

Remote Management via the Console Port . . . . . . . . . . . . . . . . . In-Band Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Powering the Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Network Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Base-T/100Base-TX Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Base-FX/1000Base-SX/LX Fiber Ports . . . . . . . . . . . . . . . . . . . . .

22 22 23 24 24 24 25 26

APPENDIX A. TECHNICAL SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Regulatory Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Base-T and 100Base-TX Ports . . . . . . . . . . . . . . . . . . . . . . . . . MDI/MDI-X Crossover Cable Wiring . . . . . . . . . . . . . . . . . . . . . . . Power Cord Set Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Country-Specific Requirements . . . . . . . . . . . . . . . . . . . . . . . . . .

27 27 27 27 27 27 28 28 29 29 29 30 30 30 31

APPENDIX B. FLOW CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 APPENDIX C. ACRONYMS & ABBREVIATIONS . . . . . . . . . . . . . . . . . . . . . . 35 INDEX

x Table of Contents

VH-4802

ELS100-48tx2m.book Page xi Thursday, November 16, 2000 4:59 PM

PREFACE Purpose This guide provides information about the features and applications of the Enterasys Networks Vertical Horizon VH-4802 switch system.

Audience This guide is intended for Ethernet Local Area Network (LAN) administrators and Management Information Systems (MIS) personnel with the following background:



Working knowledge of Ethernet LANs



Familiarity with Transmission Control Protocol/Internet Protocol (TCP/IP) and Simple Network Management Protocol (SNMP)

Conventions This section describes the conventions used in this guide.

Message Formats Two types of messages, identified by icons, appear in the text:

A note informs you of special circumstances.

A caution indicates the possibility of equipment damage.

Keyboard Entries This guide uses the following conventions for keyboard entries:

9033630



When you read “enter,” type the text and press the [Enter] key.



Example: Enter the Gateway IP address and press the [Enter] key.



When you read “select,” highlight the menu item and press the [Enter] key.

Preface xi

ELS100-48tx2m.book Page xii Thursday, November 16, 2000 4:59 PM

Other Conventions This guide uses the following typographical conventions:



Initial Caps

Menu titles and console menu selections.



[Enter]

Used to designate the Enter or Return key.



courier font

Screen messages and user prompts.



Selection

Describes a user-configurable user interface item.



Field

Describes a read-only information item.

Organization Chapter 1. Product Overview: Describes the features of the switch, front and rear panel components and application examples. Chapter 2. Installation: Describes the content of your switch shipment, lists site requirements, and provides mounting instructions. Instructions for making connections and powering up the switch are provided as well. Appendix A. Technical Specifications: Provides a list of standards compliance and certifications as well as physical and operational specifications. Appendix B. Flow Control: Describes how the flow control features are used to provide a mechanism for protecting the switch from overload conditions and to keep additional traffic off the network. Appendix C. Acronyms and Abbreviations: Provides definitions for a list of common acronyms and abbreviations used within the installation guide and the networking industry.

xii Preface

VH-4802

ELS100-48tx2m.book Page 1 Thursday, November 16, 2000 4:59 PM

1. PRODUCT OVERVIEW This chapter provides the following information:



Product Description



Features



Front and Rear Panel Component Descriptions



Feature Summaries



Application Example

Description This installation guide describes Enterasys Networks’ Vertical Horizon VH-4802 Fast Ethernet switch. The switch provides 48 10Base-T/100Base-TX ports, plus two slots for optional slide-in 100Base-FX, 1000Base-SX or 1000Base-LX modules. There is also a fixed SNMP-based management card included in the switch. This management card supports both in-band and out-of-band access for managing the switch. The switch employs a high-speed switching fabric. This design allows for simultaneous transport of multiple packets at low latency on all ports. It also uses store-and-forward switching to ensure maximum data integrity. In this mode, the entire packet must be received into a port buffer and checked for validity before being forwarded. This prevents errors from being propagated throughout the network. This switch also features fullduplex capability on all ports, which effectively doubles the bandwidth of each connection. The switch can connect up to 48 end-node workstations or servers using its 10Base-T/100Base-TX ports. Moreover, you can use a 100 Mbps fiber module for connecting to a remote site, or a Gigabit module for a highspeed backbone connection. The RMON/SNMP/Web management card provides a broad range of management options. It includes a standards-compliant Simple Network Management Protocol (SNMP) agent. The SNMP agent allows network management station applications to collect and present status and performance information about the switch, as well as providing the ability to configure and control functions in the switch. The management card also supports Remote Monitoring (RMON) for Statistics, History, Alarm and Event groups (Groups 1-3, 9). Network management can be performed in-band using a TCP/IP or Telnet connection to the switch. This card also includes a built-in Web agent that provides management access via common http browsers such as Netscape Navigator and Microsoft’s Internet Explorer. In addition, the console port allows out-of-band management using a PC, terminal, or modem connection. 9033630

Product Overview 1

ELS100-48tx2m.book Page 2 Thursday, November 16, 2000 4:59 PM

The VH-4802 switch is desktop or rack-mountable. LEDs on the front panel provide information about the operating status of the switch. The rear panel contains the power connector, redundant power connector, serial console port, and two slots for the optional modules. The side panel includes two fans that maintain ventilation and cooling for internal switch components.

Features •

Ports: - 48 dual-speed 10Base-T/100Base-TX ports using RJ-45 connectors (MDI-X) - 2 slots for optional modules - 1 serial console port - 1 redundant power unit socket



Optional Media Modules: - VHIM1000-S1SX: 1000Base-SX module provides 1 SC multimode fiber optic port for an uplink connection to the switch - VHIM1000-S1LX: 1000Base-LX module provides 1 SC singlemode fiber optic port for an uplink connection to the switch - VHIM100-S2MFX: 100Base-FX module provides 2 SC multimode fiber optic ports for an uplink connection to the switch - VHIM100-S1SFX: 100Base-FX module provides 1 SC singlemode fiber optic port for an uplink connection to the switch

Additional interface modules may be added without notice.



Switch Architecture: - 6 controllers with 8 10/100 ports - IEEE 802.3u auto-negotiation of half/full-duplex operation on all RJ-45 ports - 512 KB packet buffering for 10/100 ports, 2 MB packet buffering for 1000 ports - Store-and-forward switching - 12K address forwarding table - Forwarding: 14,880 packets-per-second (64 byte packets) @10 Mbps; 148,800 pps @100 Mbps; 1,488,000 pps @1000 Mbps - Filtering: 14,880 packets-per-second (64 byte packets) @10 Mbps; 148,800 pps @100 Mbps; 1,488,000 pps @1000 Mbps

2 Product Overview

VH-4802

ELS100-48tx2m.book Page 3 Thursday, November 16, 2000 4:59 PM

9033630



Network Management: - SNMP compliant agent: MIB II (RFC 1213); Bridge MIB (RFC 1493); Ethernet-like MIB (RFC 1643); RMON - Statistics, History, Alarm and Event groups (RFC 1757); Interface Evolution MIB (RFC 1573); Q-MIB (IEEE 802.1Q); private MIB extensions - Access via in-band, Internet browser, or Telnet - Console port (RS-232, male DB-9 connector, null modem) supports access via direct or modem connection - BootP for IP address configuration



Reliability: - Redundant power supply support



Software: - Diagnostics for product testing and troubleshooting - Firmware upgrades using the console port or in-band with TFTP



LED Indicators: - System: Power, RPU, Management - 10Base-T/100Base-TX ports: link/speed/disable, mode (flow control, full duplex, activity) - Media module ports: Status, Activity

Product Overview 3

ELS100-48tx2m.book Page 4 Thursday, November 16, 2000 4:59 PM

Front Panel Figure 1-1 shows the front panel of the Enterasys Networks Vertical Horizon VH-4802. Table 1-1 defines the VH-4802 front panel components.

Figure 1-1. VH-4802 Front Panel Table 1-1. Front Panel Components Name

Function

Power LED

Lights steady green to indicate power is supplied to the switch. Off indicates no power is supplied to the switch.

RDP LED

Lights steady to indicate that a redundant power unit is attached and is in backup or active mode.

Mgmt LED

Lights steady to indicate that the management is in operational mode.

Link LEDs

Yellow indicates a 10 Mbps link; green indicates a 100 Mbps link, off indicates no link; and flashing indicates that the port has been manually disabled.

Mode LEDs

The Mode Select button selects the LED display mode. Act: Flashing indicates activity on the port segment. FDX: Lights steady to indicate full-duplex operation. Flow Ctrl: Lights steady to indicate that flow control is enabled for the port.

Module LEDs

Status: Indicates a module is installed in the slot. Activity: Flashing indicates activity on the module.

10Base-T/100Base-TX RJ-45 ports

4 Product Overview

Copper ports using RJ-45 port connectors. All the ports are wired MDI-X.

VH-4802

ELS100-48tx2m.book Page 5 Thursday, November 16, 2000 4:59 PM

Optional Modules Figure 1-2 shows the optional modules available for the Enterasys Networks Vertical Horizon VH-4802. Table 1-2 defines the optional module components.

Figure 1-2. Optional Modules Table 1-2. Optional Module Components Module

Components

100Base-FX (MMF)

Ports: Two multi-mode fiber ports using SC connectors for uplink. (See 100Base-FX/1000Base-SX/LX Fiber Ports on page 26 for a detailed description.)

100Base-FX (SMF)

Ports: One single-mode fiber port using SC connectors for uplink. (See 100Base-FX/1000Base-SX/LX Fiber Ports on page 26 for a detailed description.)

1000Base-SX

Ports: One fiber port using SC connectors for uplink. (See 100Base-FX/1000Base-SX/LX Fiber Ports on page 26 for a detailed description of these ports.)

1000Base-LX

Ports: One fiber port using SC connectors for uplink. (See 100Base-FX/1000Base-SX/LX Fiber Ports on page 26 for a detailed description of these ports.)

9033630

Product Overview 5

ELS100-48tx2m.book Page 6 Thursday, November 16, 2000 4:59 PM

Rear Panel Figure 1-3 shows the VH-4802 rear panel and Table 1-3 defines the rear panel components.

Figure 1-3. VH-4802 Rear Panel Table 1-3. Rear Panel Components Name

Function

Power Connector

Provides AC power to the switch.

Redundant Power Connector

This connector is provided for the option of adding an additional DC redundant power unit (RPU) which can supply power to the switch if its primary power supply fails. (Refer to the manual provided with the RPU for further details.)

Management Connector

The management card’s serial console port provides out-of-band access to the switch.

Slots for Optional Modules

The two slots support optional media modules.

6 Product Overview

VH-4802

ELS100-48tx2m.book Page 7 Thursday, November 16, 2000 4:59 PM

Feature Summaries The following summaries describe VH-4802 features in areas such as standards compliance, functionality, performance, and options.

IEEE 802.1D Bridge The VH-4802 switch is fully compliant with IEEE 802.1D transparent bridging specifications. An address table is provided for learning, filtering, and forwarding. The switch can support up to a maximum of 12K addresses. Addresses are automatically learned by the switch, and can be individually assigned specific forwarding treatment by the network administrator if desired. Forwarding table configuration can be made outof-band via the console interface or in-band via SNMP or Telnet. Static and dynamic addresses are both stored in this table. One static address is assigned per port by default. The Static Unicast Address Table Configuration screen in the console menus allows you to assign additional static addresses if required.

Spanning Tree Protocol The VH-4802 switch supports the IEEE 802.1D Spanning Tree Protocol. This protocol allows redundant connections to be created between different LAN segments for purposes of fault tolerance. Two or more physical paths between different segments can be created through the switch, with the Spanning Tree Protocol choosing a single path at any given time and disabling all others. If the chosen path fails for any reason, a disabled alternative is activated, thereby maintaining the connection. This prevents network traffic from circulating in an endless loop formed by multiple connections to the same LAN segment. Spanning Tree parameters are configurable using the Spanning Tree Configuration Menu of the console menus, the on-board Web agent, or via SNMP (see Appendix B, “Spanning Tree Concepts,” in the Management Guide for more information).

Frame Buffering and Frame Latency The VH-4802 switch is a store-and-forward switching device. Each frame is copied into switch memory before being forwarded to another port. This method ensures that all forwarded frames conform to a standard Ethernet frame size and have a correct cyclic redundancy check (CRC) for data integrity. This switching method prevents bad frames from traversing the network and using up valuable network bandwidth, as with cut-through switching technology. To minimize the possibility of dropping frames on congested ports, the VH-4802 switch provides 512 KB of frame buffering per port. This buffer space is used to queue packets for transmission on congested networks. This is an additional advantage over cut-through switching technology, which drops packets immediately when experiencing collisions.

9033630

Product Overview 7

ELS100-48tx2m.book Page 8 Thursday, November 16, 2000 4:59 PM

Software Download The VH-4802 switch supports the industry-standard Trivial File Transfer Protocol (TFTP) for downloading software to the switch. All switch software is stored in a 2 MB sectored flash ROM. The download feature allows you to easily install software upgrades to the unit. Software can alternatively be downloaded via the serial console port using the XMODEM protocol. A TFTP software download is invoked via the Management Setup Menu using the console menus. A TFTP download can also be invoked using the on-board Web agent or via SNMP.

Non-Volatile Parameter Storage Important operating parameters such as IP addresses, Spanning Tree configuration, and management security parameters, are stored in nonvolatile flash memory. These values are retained when the switch experiences power interruptions or is powered down for normal maintenance.

Configuration and Management Interfaces The VH-4802 switch can be managed using any of the following methods:



Serial console, out-of-band An RS-232 connection, using a DB-9 connector, is included on the rear panel for system management. Serial console management can be performed out-of-band using a terminal or computer running communications software. You can connect directly to the RS-232 port on the rear panel, or make a connection via a modem. See the Management Guide for information on managing the VH-4802 switch via the serial console.



Telnet, in-band (over Ethernet) The switch supports management through a Telnet connection using the TCP/IP protocols. Telnet is performed using a terminal or computer running communications software. See the Management Guide for information on managing the system via Telnet. Global user name and password protection for changing the operating parameters of the switch is provided.



Web-based network manager, in-band The system can be managed over HTTP protocol with a Web browser (Internet Explorer 4.0 or above, or Netscape Navigator 4.0 or above). Standard agent MIBs embedded in the switch provide basic SNMP management through an embedded graphic interface.

8 Product Overview

VH-4802

ELS100-48tx2m.book Page 9 Thursday, November 16, 2000 4:59 PM



SNMP-based network manager, in-band The system can also be managed using SNMP, the most common protocol used today for network management. Standard agent MIBs embedded in the switch provide basic SNMP management through industry-standard SNMP applications. Management security protection is provided based on SNMP community names. See Chapter 4, “SNMP Management,” in the Management Guide for more information.

RMON RMON (Remote Monitoring) is a facility used to manage networks remotely while providing multi-vendor interoperability between monitoring devices and management stations. RMON is defined by an SNMP MIB. This MIB is divided into nine different groups, each gathering specific statistical information or performing a specific function. RMON-capable devices gather network traffic data and then store them locally until downloaded to an SNMP management station. The VH-4802 supports four of the nine groups of RMON defined for Ethernet networks on a per segment basis. Specifically, these are:



Statistics: a function that maintains counts of network traffic statistics such as number of packets, broadcasts, collisions, errors, and distribution of packet sizes.



History: a function that collects historical statistics based on userdefined sampling intervals. The statistical information collected is the same as the Statistics group, except on a time stamped basis.



Alarm: a function that allows managers to set alarm thresholds based on traffic statistics. Alarms trigger other actions through the Event group.



Event: a function that operates with the Alarm group to define an action that will be taken when an alarm condition occurs. The event may write a log entry and/or send a trap message.

Note that RMON statistics and other information can only be viewed using a connection to the on-board Web agent or via other compatible SNMP management applications.

Port Mirroring The VH-4802 switch includes the ability to mirror the traffic being switched on any port for purposes of network traffic analysis and connection integrity. When this feature is enabled, a protocol analyzer or RMON probe can be connected to the mirror port. You can only mirror one port to another port at one time. Port mirroring occurs at the same speed configured for the port (10Mbps-to-10Mbps or 100Mbps-to-100Mbps). Port mirroring is configurable using the console interface menus, the onboard Web agent, or via SNMP.

9033630

Product Overview 9

ELS100-48tx2m.book Page 10 Thursday, November 16, 2000 4:59 PM

Auto-negotiation Auto-negotiation is a process that permits the switch to automatically select the operational modes of its 10/100 RJ-45 ports. Upon first being connected, the switch detects the speed of the network the port is connected to, either 10Mbps or 100Mbps, and the type of communication setting, half or full duplex. The port is then automatically set by the switch to operate in the proper mode, without user intervention. It is not required that the network device being connected to the switch supports autonegotiation as the VH-4802 switch automatically adjusts to the network device’s communication settings. Auto-negotiation is configurable using the console interface menus, the on-board Web agent, or via SNMP.

BootP The Bootstrap Protocol (BootP) provides for the capability of passing configuration information to hosts on a TCP/IP network. Using this process, network devices do not need to be configured before they can communicate using the TCP/IP protocol suite. The VH-4802 switch uses BootP to automatically configure IP address information without requiring access to the console menus. BootP operation is configurable using the console interface menus, the on-board Web agent, or via SNMP.

LEDs The switch port LEDs provide a quick and accurate display of the integrity of switch connections and port mode. Each RJ-45 port has a Link and Mode LED. The color of the Link LED indicates a 10 Mbps or 100 Mbps connection. The operation of the Mode LEDs can be changed by use of the LED Mode button on the switch front panel. When the LED Mode button is pressed, the operation of the RJ-45 Mode LEDs changes to indicate Activity (Act) and full/half duplex operation (FDX), and flow control (Flow Ctrl) respectively. The module LEDs indicate Status and Activity for each of the modules. The module LEDs are not affected by the LED Mode button.

Full Duplex Mode The full-duplex mode of operation on a port can double the throughput of switch connections. This mode disables the collision detection portion of the Ethernet Carrier Sense Multiple Access with Collision Detection (CSMA/CD) protocol, allowing for two-way traffic. Full duplex is configurable using the console interface menus, the on-board Web agent, or via SNMP.

10 Product Overview

VH-4802

ELS100-48tx2m.book Page 11 Thursday, November 16, 2000 4:59 PM

Flow Control Flow control allows you to manage network traffic during congestion periods and to prevent the loss of packets when port buffer thresholds are exceeded. Flow control also serves to deny access to additional traffic that could add to a congestion condition. The VH-4802 switch supports flow control per the IEEE 802.3x standard. Note that flow control is disabled on all ports by default but can be enabled on a per-port basis by using the console interface menus, the on-board Web agent, or via SNMP. See Appendix B, “Flow Control,” for more information on this feature. If flow control is desired for one port, it is recommended that it be enabled on all ports. However, note that flow control should not be used if a port is connected to a hub. Also, be aware that when interconnecting high-speed LANs (such as Gigabit Ethernet) and low-speed LANs, flow control can cause traffic from the high-speed LAN to be blocked for all other ports on the switch.

Virtual LANs (VLANs) VLANs allow you to connect users to a specific LAN segment regardless of their physical location. The VH-4802 switch supports tagged VLANs per the IEEE 802.1Q draft standard. With frame tagging, a short tag is appended to every frame that crosses the network backbone. The tag identifies which VLAN the frame belongs to. See Appendix B, “Virtual LANs,” in the Management Guide for more information.

Class of Service Class of Service support allows you to assign a higher priority to selected traffic passing through the switch. The VH-4802 switch supports Class of Service attributes per the IEEE 802.1p standard using a priority queuing mechanism. This feature ensures that traffic during congestion periods will not interfere with traffic assigned a higher priority. Traffic assigned a lower priority is subject to discard when memory is in short supply. See Appendix C, “Class of Service,” in the Management Guide for more information.

Port Trunking Port trunking allows you to combine ports into an aggregate connection between VH-4802 switches. Besides balancing the load across each port in the trunk, the additional ports provide redundancy by taking over the load if a port in the trunk should fail. The VH-4802 allows up to four ports of the same media type to be joined together as a trunk. RJ-45 ports must be selected from pre-determined port groups, and 100Mbps fiber ports must be on the same module, but both 1000Mbps module ports can be combined together. Up to eight port trunks on a single VH-4802 switch can be configured.

9033630

Product Overview 11

ELS100-48tx2m.book Page 12 Thursday, November 16, 2000 4:59 PM

Factory Defaults Table 1-4 lists the default settings for switch configuration parameters. Each parameter can be changed via the console menus or Telnet. Table 1-4. Factory Default Settings Parameter

Default Value

Multicast Filtering GMRP

Disabled

IGMP Multicast Filtering

Disabled

Port Configuration Flow Control

Disabled

Speed and Duplex

Auto

Admin

Enabled

Broadcast Storm Control

Enabled - 500 pps

Port Priority Default Ingress User Priority

0

Spanning Tree Algorithm Active Aging Time

300

Bridge Priority

32768

Forward Delay

15

Hello Time

2

Max Age

20

Path Cost

4 - 1000Mbps ports 19 - 100Mbps ports 100 - 10Mbps ports

Port Priority

128

Spanning Tree Protocol

Enabled

System Configuration Management VLAN

All

BootP Enable

Disabled

Password



Screen Timeout

10 min

Send Authentication Fail Traps

Enabled

SNMP Community Name

public, private

Terminal Baud Rate

Auto

User Names

admin, guest

12 Product Overview

VH-4802

ELS100-48tx2m.book Page 13 Thursday, November 16, 2000 4:59 PM

Parameter

Default Value

Virtual LANs Acceptable VLAN Frame Type

9033630

All

Configurable PVID Tagging

Yes

GVRP

Disabled

Untagged VLAN Group Assignment

1

VLAN Ingress Filtering

False

VLAN Learning

SVL

Product Overview 13

ELS100-48tx2m.book Page 14 Thursday, November 16, 2000 4:59 PM

Application Examples The exploding popularity of the Internet and of corporate intranets, as well as new, high-bandwidth desktop applications, are driving the demand for Fast Ethernet. The increase in multimedia traffic and the need to support legacy protocols alongside new, data intensive applications is driving the need for network segmentation and traffic prioritization. The VH-4802 switch is ideal for meeting the needs of today’s high performance networks. The switch’s low cost and high port count makes it attractive and affordable for dedicated 10/100Mbps connections to the desktop. In addition, extensive features, including redundant links, traffic Class of Service and VLAN capability, provide the management needed for the workgroup and local backbone. The following sections illustrate the VH-4802 switch employed in application examples:



Client/Server Network



Local Backbone

14 Product Overview

VH-4802

ELS100-48tx2m.book Page 15 Thursday, November 16, 2000 4:59 PM

Client/Server Network Application To improve workstation performance in a client/server environment, the VH-4802 switch can be configured to provide 200 Mbps full duplex Fast Ethernet connections to servers by connecting each to a dedicated switch port (Figure 1-4). Users can be accommodated through connections to hubs, both at 10Mbps and 100Mbps speeds, through 10Mbps switches with 100Mbps uplinks, or through direct connections. The fiber uplinks are available to connect the switch to a remote location, such as another building floor or a separate building.

Figure 1-4. Client/Server Network Application

9033630

Product Overview 15

ELS100-48tx2m.book Page 16 Thursday, November 16, 2000 4:59 PM

Local Backbone Application The VH-4802 switch can be used in a local backbone application, connecting network segments together and providing file-server access (Figure 1-5). Workgroup hubs are provided with a single connection to the switch while servers are put on dedicated 100 Mbps ports. Routers and other networking devices can connect off of the switched backbone as well. The fiber uplinks are available to connect the switch to a remote location, such as another building floor or a separate building.

Figure 1-5. Local Backbone Application

16 Product Overview

VH-4802

ELS100-48tx2m.book Page 17 Thursday, November 16, 2000 4:59 PM

2. INSTALLATION Inspecting Your Shipment When you receive the shipment of your switch, check the package contents and make sure you have the following items:



VH-4802 switch



Mounting ears and mounting screws



Four rubber feet



ESD wrist strap



Power cord



RS-232 null-modem cable



Product documentation

Site Requirements Before you install the switch, make sure the site meets the following requirements:



Mounting Provide a flat table, shelf surface, or an optional 19 in. (48.3 cm) equipment rack. Use an EIA standard equipment rack that is grounded and physically secure.



Power source Provide a power source within six feet (1.8 m) of the installation location. This source must provide 100 VAC to 240 VAC at 50 Hz to 60 Hz, for 90 VA minimum power. Power specifications for the switch are shown in Appendix A, “Technical Specifications.”

Primary voltage selection within the above ranges is automatic and requires no user action.

9033630

Installation 17

ELS100-48tx2m.book Page 18 Thursday, November 16, 2000 4:59 PM



Environmental Install the VH-4802 switch in a dry area, with adequate air circulation. Avoid placing the switch in direct sunlight or near other heat sources, such as hot-air vents. For temperature and humidity specifications, see Appendix A, “Technical Specifications.”



Ventilation Do not restrict airflow by covering or obstructing air inlets on the side of the switch.

Mounting the Switch on a Table or Shelf You can mount the switch on a table or shelf. Locate the switch in a position that allows access to the front panel RJ-45 ports, visibility of the port LEDs, and access to the rear-panel modules and power cord. Make sure that the mounting surface can safely support the switch and that there is adequate space around the switch for ventilation and cooling. 1.

The switch ships with four (4) rubber feet. Stick the self-adhesive rubber foot pads on each of the four concave spaces located on the bottom of the switch. The rubber foot pads cushion the switch against shock/vibrations and provide space between each switch for ventilation.

2.

If you want to stack switches, repeat step 1 for each switch to be stacked. Place the first switch on a firm flat surface where you want to install the stack. Stack the other switches on top of this unit.

18 Installation

VH-4802

ELS100-48tx2m.book Page 19 Thursday, November 16, 2000 4:59 PM

Mounting the Switch in a Rack The switch ships with two (2) multi-position mounting ears and four (4) mounting screws. The mounting screws are used to attach the mounting ears to the switch. Once the ears are attached to the switch, you will need to provide appropriate screws to mount the switch in a rack.

Figure 2-1 shows the orientation of the mounting ears for attaching the ears to the switch for a rack mount application. Mount the switch with the front panel facing forward. Do the following: 1.

Mount one of the ears to the switch using two (2) of the supplied screws. Repeat this step for the other side of the switch.

2.

Slide the switch into the rack and align the holes in the rack mounting ears with the holes in the rack rails.

3.

Insert and tighten appropriate rack-mounting screws (not provided).

Figure 2-1. Mounting the Switch in a Rack

9033630

Installation 19

ELS100-48tx2m.book Page 20 Thursday, November 16, 2000 4:59 PM

Installing an Optional Module into the Switch Optional modules are available for media expansion. These modules can be installed into either of the two modular slots on the rear panel of the switch. DO NOT install slide-in modules with the switch powered on. Be sure you power off the switch before installing any module.

To install an optional module into the switch, do the following: 1.

Disconnect power to the switch.

2.

Remove the blank metal plate (or a previously installed module) from the appropriate slot by removing the two screws with a flat-head screwdriver.

3.

Before opening the package that contains the module, touch the bag to the switch casing to discharge any potential static electricity. Also, use the ESD wrist strap included with the package.

4.

Remove the module from the anti-static shielded bag.

5.

Holding the module level, guide it into the carrier rails on each side and gently push it all the way into the slot, ensuring that it firmly engages with the connector.

Figure 2-2. Installing an Optional Module into the Switch 6.

If you are sure the module is properly mated with the connector, tighten the retainer screws by hand to secure the module in the slot.

7.

Connect power to the switch.

20 Installation

VH-4802

ELS100-48tx2m.book Page 21 Thursday, November 16, 2000 4:59 PM

Connecting a Terminal to the Console Port The console port is a serial RS-232 interface port that enables a connection to a terminal for performing switch monitoring and configuration functions. The terminal may be a PC or workstation running terminal emulation software, or a terminal configured as a Data Terminal Equipment (DTE) connection. Alternatively, this port can be connected to an external modem to enable remote dial-in management. You can use the out-of-band management program (described in the Management Guide) over a standard modem connection. If you connect a terminal to the console port prior to powering on the switch, you can observe the progress and results of the power-on self test as the switch goes through its initialization process. See “Powering the Switch” on page 23. The console port is configured as a standard RS-232 connection using a male DB-9 connector (see Table A-1 for pinouts). A null-modem wired RS-232 cable is supplied with the switch for connecting to this interface. This cable is shielded to comply with emissions regulations and requirements.

Console Port (Out-of-Band) Connections To connect the VH-4802 console port to a terminal, do the following: 1.

Connect a VT100 compatible terminal or a PC running a terminal emulation program to the console port (Figure 2-3). Use the nullmodem cable provided with the switch, or use a null-modem connection that is compatible with the console port pin assignments shown in Appendix A.

Figure 2-3. Connecting a Terminal to the Console Port 2.

9033630

Connect one end of the interface cable directly to the switch’s console port and tighten the retaining screws.

Installation 21

ELS100-48tx2m.book Page 22 Thursday, November 16, 2000 4:59 PM

3.

Connect the other end of the interface cable to a terminal (in some instances, an adapter may be required to make this connection).

4.

From your terminal, start the terminal emulation program.

5.

Configure the terminal to the following communication settings: VT100 emulation, 19200 baud, no parity, 8 data bits, 1 stop bit, no flow control, ASCII character set.

Remote Management via the Console Port Configure the Switch Site - Connect the switch’s DB-9 serial port to the modem’s serial port using standard cabling. For most modems using a 25-pin port, you will have to provide an RS-232 cable with a 9-pin connector on one end and a 25-pin connection on the other end. You do not have to set the modem at the switch’s site, because the switch will automatically configure it to auto-answer mode. Configure the Remote Site - At the remote site, connect the PC’s COM port (COM 1-4) to the modem’s serial port. Set terminal emulation type to VT100, specify the port used by your PC (i.e., COM 1-4), then set communications to 8 data bits, 1 stop bit, no parity, 19200 bps, and no flow control.

In-Band Connections Prior to accessing the switch via a network connection, you must configure it with a valid IP address, subnet mask, and default gateway using an out-of-band connection or the BootP protocol. The switch must first be configured to issue BootP requests, since the default is BootP disabled. Refer to the Management Guide for more information.

Telnet Connection - Prior to accessing the switch via an in-band Telnet connection, you must configure it with a valid IP address, subnet mask, and default gateway using an out-of-band connection or the BootP protocol. After configuring the switch’s IP parameters, you can access the on-board configuration program from anywhere within the attached network. In-Band Network Connection - The on-board configuration program can be accessed using Telnet from any computer attached to the network. The switch can also be managed by any computer using a Web browser (Internet Explorer 4.0 or above, or Netscape Navigator 4.0 or above), or from a network computer using third-party network management software.

22 Installation

VH-4802

ELS100-48tx2m.book Page 23 Thursday, November 16, 2000 4:59 PM

Powering the Switch To supply power to the switch, connect the power cord to the switch and to a grounded three-prong wall outlet (Figure 2-4). See Appendix A, “Technical Specifications” on page 27 for more information regarding specific international power cord requirements.

Figure 2-4. Connecting the Power Cord The Power LED lights green (see Figure 1-1). If it does not, check to make sure that the power cable is plugged in correctly and that the power source is good. When power is applied, the switch conducts a series of hardware and software tests to verify operation. If a terminal or computer is connected to the console port, the results of the tests are displayed on the screen. If you want to display the results of the tests after the switch has been turned on, turn the power to the switch off then back on. The switch performs two basic types of tests at power-up. During this time, all the LEDs light in sequence. These tests are:



Serial port The serial console port test is the first test. If the switch fails, no further tests are performed and the console displays no information.



Memory Memory tests on the CPU RAM are performed after the serial port test. No results are displayed on the console.

After these tests are performed, the system initialization screen provides the option of starting the operational software of the switch or performing an XMODEM download to upgrade system firmware. When the operational software is started, the system is functional and the user interface is ready to receive commands at the console.

9033630

Installation 23

ELS100-48tx2m.book Page 24 Thursday, November 16, 2000 4:59 PM

Network Cable Requirements Copper Figure 2-1 specifies the cable types and length constraints for the various copper interfaces on the VH-4802. Table 2-1. Copper Cable Specifications Interface Type

Cable Requirement

Maximum Length

10Base-T

Category 3 or 5 Unshielded Twisted Pair (UTP)

100m (328 ft.)

100Base-TX

Category 5 UTP

100m (328 ft.)

Fiber Figure 2-2 specifies the fiber types, bandwidth requirements, and length constraints for the Fast Ethernet fiber interface on the fiber optic media modules. Table 2-2. Fast Ethernet Fiber Specifications Interface Type

Fiber Type

Fiber Diameter (microns)

Maximum Length (m)

100Base-FX (SC connectors)

multi-mode

62.5

2,000m (6,560 ft.)

100Base-FX (SC connectors)

single-mode

10

10 km (6.21 miles)

Figure 2-3 specifies the fiber types, bandwidth requirements, and length constraints for the Gigabit Ethernet short-wavelength fiber interface on the fiber optic media module. Table 2-3. 1000Base-SX Fiber Specifications Fiber Diameter (microns)

Modal Bandwidth @ 850 nm

Range

62.5 µm MMF

160 MHz/km

2-220 Meters

62.5 µm MMF

200 MHz/km

2-275 Meters

50 µm MMF

400 MHz/km

2-500 Meters

50 µm MMF

500 MHz/km

2-550 Meters

24 Installation

VH-4802

ELS100-48tx2m.book Page 25 Thursday, November 16, 2000 4:59 PM

Figure 2-4 specifies the fiber types, bandwidth requirements, and length constraints for the Gigabit Ethernet long-wavelength fiber interface on the fiber optic media module. Table 2-4. 1000Base-LX Fiber Specifications Fiber Diameter (microns)

Modal Bandwidth @ 1300 nm

Range

62.5 µm MMF

500 MHz/km

2-550 Meters

50 µm MMF

500 MHz/km

2-550 Meters

50 µm MMF

400 MHz/km

2-550 Meters

10 µm SMF

N/A

2-5000 Meters

10Base-T/100Base-TX Ports The 10Base-T/100Base-TX ports use RJ-45 connectors. Figure 2-5 shows an RJ-45 connector being inserted into a port.

Figure 2-5. Inserting an RJ-45 Connector into a Port The ports on the base unit are wired with the MDI-X function implemented. These ports interface to UTP cabling for connection to 10Base-T or 100Base-TX network segments or end-stations. These UTP connections meet the requirements of ISO 8877, specified by 10Base-T, Section 14 of the IEEE 802.3 specification. Workstations or servers can be connected to these ports using standard straight-through wired cables. For connections to other switches or hubs, use an MDI port on the other device. If an MDI port is not available, a crossover cable may be necessary (refer to “MDI/MDI-X Crossover Cable Wiring” in Appendix A). See Table A-2, “10Base-T/100Base-TX Pinouts,” for 10Base-T/ 100Base-TX connector pin assignments.

9033630

Installation 25

ELS100-48tx2m.book Page 26 Thursday, November 16, 2000 4:59 PM

100Base-FX/1000Base-SX/LX Fiber Ports The 100Base-FX and 1000Base-SX/LX fiber ports use SC connectors. Figure 2-6 shows an SC fiber connector being inserted into a fiber port on the VH-4802.

Figure 2-6. Inserting an SC Fiber Connector into a Fiber Port The fiber uplink modules employed (Table 2-5) support multi-mode 62.5/ 125µm fiber and single-mode 10/125µm fiber. The 100Base-FX and 1000Base-SX/LX ports use SC fiber connectors. The fiber connectors are configured as a receive (RX) / transmit (TX) pair. Table 2-5. Fiber Uplink Modules Part Number

Functions

Description

VHIM100-S2MFX

100Base-FX-MM

Dual-port multi-mode (MM) fiber uplink module using SC fiber connectors.

VHIM100-S1SFX

100Base-FX-SM

Single-port single-mode (SM) fiber uplink module using SC fiber connectors.

VHIM1000-S1SX

1000Base-SX-MM

Single-port multi-mode (MM) fiber uplink module using SC fiber connectors.

VHIM1000-S1LX

1000Base-LX-SM

Single-port single-mode (SM) fiber uplink module using SC fiber connectors.

26 Installation

VH-4802

ELS100-48tx2m.book Page 27 Thursday, November 16, 2000 4:59 PM

APPENDIX A. TECHNICAL SPECIFICATIONS General Standards Compliance IEEE 802.1D Transparent Bridging Specifications (ISO/IEC 10038) IEEE 802.1p Traffic Class Expediting and Dynamic Multicast Filtering IEEE 802.1Q Virtual Bridged Local Area Networks IEEE 802.2 Local Area Networks, Logical Link Control (LLC) IEEE 802.3 CSMA/CD 9 (ISO/IEC 8802-3) IEEE 802.3i 10Base-T (ISO/IEC 8802-3, clause 14) IEEE 802.3u 100Base-TX (ISO/IEC 8802-3, clause 25) IEEE 802.3u 100Base-FX IEEE 802.3z 1000Base-SX, 1000Base-LX IEEE 802.3x Flow Control EIA RS-232C (DTE-to-DCE) EIA RS-310C (19” rackmount)

Regulatory Compliance Safety: UL 1950, CSA C22.2 No 950, 73/23/EEC, EN 60950, IEC 950 Electromagnetic Compatibility (EMC): FCC Part 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000-3-2, EN 61000-3-3, EN 50082-1, AS/NZS 3548, VCCI V-3

Data Rate 10 Mbps Manchester encoded, 100 Mbps 4B/5B encoded, 1000 Mbps 8B/10B encoded.

Environmental Specifications

9033630

Operating temperature:

32° to 122° F (0° to 50° C)

Operating humidity:

5 to 95% relative, non-condensing

Storage temperature:

-40° to 158° F (-40° to 70° C)

Storage humidity:

5 to 95% relative, non-condensing

Technical Specifications 27

ELS100-48tx2m.book Page 28 Thursday, November 16, 2000 4:59 PM

Electrical Specifications Input voltage:

100-240 VAC

Input frequency:

50-60 Hz

Maximum power consumption:

90 VA

Physical Specifications Height:

3.3 in. (8.4 cm)

Length:

13.8 in. (35 cm)

Width:

17.3 in. (44 cm mountable in a standard 19 in. rack)

Weight:

10.63 lb. (4.82 kg)

28 Technical Specifications

VH-4802

ELS100-48tx2m.book Page 29 Thursday, November 16, 2000 4:59 PM

Port Specifications Console Port Table A-1 shows the console port pin assignments. Table A-1. RS-232 Console Port Pin Assignments Pin

Signal Name

1

DCD

2

RXD

3

TXD

4

DTR

5

Ground

6

DSR

7

RTS

8

CTS

9

RI

10Base-T and 100Base-TX Ports Table A-2 shows the 10Base-T/100Base-TX pinouts. These ports are wired MDI-X. All undefined pins are not used. Table A-2. 10Base-T/100Base-TX Pinouts

9033630

Pin

MDI-X Signal Name

1

RD+

2

RD-

3

TD+

6

TD-

Technical Specifications 29

ELS100-48tx2m.book Page 30 Thursday, November 16, 2000 4:59 PM

MDI/MDI-X Crossover Cable Wiring Figure A-1 shows the wiring scheme for implementing a crossover cable if needed for connection to the switch’s 10Base-T or 100Base-TX ports. Such a cable may be required when connecting the switch to another switch or a hub device.

Figure A-1. External Crossover Cable Wiring

Power Cord Set Requirements The wide-range input feature of the VH-4802 Ethernet switch permits it to operate from any line voltage between 100 and 240 VAC. The power cord set (appliance coupler, flexible cord, and wall plug) you received with the switch meets the requirements for use in the country where you purchased the switch. Power cord sets for use in other countries must meet the requirements of the country where you use the switch. For more information on power cord set requirements, contact your Enterasys Networks Support Representative.

General Requirements The requirements listed below are applicable to all countries:



The length of the power cord set must be at least 5.00 feet (1.5 m) and a maximum of 6.56 feet (2.0 m).



All power cord sets must be approved by an acceptable accredited agency responsible for evaluation in the country where the power cord set will be used.



The power cord set must have a minimum current capacity of 10A and a nominal voltage rating of 125 or 250 VAC, as required by each country’s power system.



The appliance coupler must meet the mechanical configuration of an EN 60 320/IEC 320 Standard Sheet C13 connector for mating with appliance inlet on the hub.

30 Technical Specifications

VH-4802

ELS100-48tx2m.book Page 31 Thursday, November 16, 2000 4:59 PM

Country-Specific Requirements Table A-3 lists the power cord set requirements by country and identifies the accredited agency within that country. Table A-3. Power Cord Set Requirements by Country Country

Accredited Agency

See Notes *

Australia

EANSW

1

Austria

OVE

1

Belgium

CEBC

1

Canada

CSA

2

Denmark

DEMKO

1

Finland

FIMKO

1

France

UTE

1

Germany

VDE

1

Italy

IMQ

1

Japan

JIS

3

Netherlands

KEMA

1

Norway

NEMKO

1

Sweden

SEMKO

1

Switzerland

SEV

1

United Kingdom

BSI

1

United States

UL

2

* The note column includes a number. Associate this number with the corresponding notes listed after the table to obtain specific power standards and requirements.

Note 1 Flexible cord must be Type HO5VV-F or HO3VV-F, 3-conductor, 1.0 mm2, or 0.75 mm2 conductor size. Power cord set fittings (appliance coupler and wall plug) must bear the certification mark of the agency responsible for evaluation in the country where it will be used.

9033630

Technical Specifications 31

ELS100-48tx2m.book Page 32 Thursday, November 16, 2000 4:59 PM

Note 2 Flexible cord must be Type SV, SJ, SPT or equivalent, No. 18 AWG, 3-conductor. Wall plug must be a two-pole grounding type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A 250V) configuration.

Note 3 Appliance coupler, flexible cord, and wall plug must bear a “T” mark and registration number in accordance with the Japanese Dentori Law. Flexible cord must be Type VCT or VCTF, 3-conductor, 0.75mm2 conductor size. Wall plug must be a two-pole grounding type with a Japanese Industrial Standard C8303 (15A, 125V) configuration.

32 Technical Specifications

VH-4802

ELS100-48tx2m.book Page 33 Thursday, November 16, 2000 4:59 PM

APPENDIX B. FLOW CONTROL Flow control is a mechanism which allows you to protect the switch from overload conditions and to keep additional traffic off the network when excessive congestion will result. Figure B-1 illustrates flow control for both half- and full-duplex applications.

Figure B-1. Flow Control for Half- and Full-Duplex Applications Each port of the switch has a transmit queue which buffers frames to be sent out on that port. In this example, large amounts of data are being sent from Workstation A (connected to port X) and other ports on the switch to Workstation B (connected to port Y).The queue on port Y starts filling up with data until it reaches a determined threshold. The packet which causes the threshold to be exceeded triggers the flow-control function on the port from which the packet entered the switch, in this case port X. Since port X is configured with flow control set to Enabled, the switch responds by initiating a pause frame (full-duplex applications) or backpressure mechanism (half-duplex applications). The pause frame causes Workstation A to stop sending packets. After a certain amount of time has elapsed, determined by a value in the pause frame, Workstation A will resume sending data. Similarly, the back-pressure mechanism forces Workstation A to stop sending packets by inducing collisions on port X. The pause-frame flow-control mechanism supported by the VH-4802 switch conforms with the IEEE 802.3x specification for fullduplex flow control. For the full-duplex pause-frame mechanism to work, the device connected to the switch port must also support IEEE 802.3x flow control. Flow control is configurable per port in the Port Configuration Menu of the console menus, using the on-board Web agent, or via SNMP.

9033630

Flow Control 33

ELS100-48tx2m.book Page 34 Thursday, November 16, 2000 4:59 PM

34 Flow Control

VH-4802

ELS100-48tx2m.book Page 35 Thursday, November 16, 2000 4:59 PM

APPENDIX C. ACRONYMS & ABBREVIATIONS

9033630

Term

Definition

10Base-T

10 Mbps twisted-pair Ethernet

100Base-TX

100 Mbps twisted-pair Fast Ethernet

100Base-FX

100 Mbps fiber option Fast Ethernet

1000Base-SX

1000 Mbps fiber option short-wavelength Gigabit Ethernet

1000Base-LX

1000 Mbps fiber option long-wavelength Gigabit Ethernet

ANSI

American National Standards Institute

BootP

Bootstrap Protocol

CAT5

Category 5

CRC

Cyclic Redundancy Check

CSMA/CD

Carrier Sense Multiple Access/Collision Detection

DCE

Data Communications Equipment (modem)

DSR

Data Send Ready

DTE

Data Terminal Equipment

DTR

Data Terminal Ready

ESD

Electrostatic Discharge

FCS

Frame Check Sequence

HTTP

Hypertext Transfer Protocol

ICMP

Internet Control Message Protocol

IEEE

Institute of Electrical and Electronics Engineers

IP

Internet Protocol

LAN

Local Area Network

MAC

Media Access Control

MDI

Media Dependent Interface

LED

Light Emitting Diode

MDI

Media Device Interface

MIB

Management Information Base

RFC

Request for Comment

RMON

Remote Monitoring

RXD

Receive Data

Acronyms & Abbreviations 35

ELS100-48tx2m.book Page 36 Thursday, November 16, 2000 4:59 PM

Term

Definition

SNMP

Simple Network Management Protocol

TCP/IP

Transmission Control Protocol/Internet Protocol

TFTP

Trivial File Transfer Protocol

TXD

Transmit Data

UTP

Unshielded Twisted Pair

VLAN

Virtual LAN

36 Acronyms & Abbreviations

VH-4802

ELS100-48tx2m.book Page 1 Thursday, November 16, 2000 4:59 PM

INDEX

1000Base-LX cables, 25 module defined, 5 1000Base-SX cables, 24 module defined, 5 100Base-FX modules defined, 5 10Base-T/100Base-TX ports, 25 802.1D, 7 802.1p, 11 802.1Q, 3, 11 802.3, 25 802.3x, 11

A activity LEDs, 4 application examples, 14 architecture of switch, 2 auto-negotiation, 2, 10

B back-pressure flow control, 33 BootP, 10, 22 browsers, Web, 8, 22 buffers, frame, 7

C cable requirements, 24 Class of Service, 11 client/server application, 15 communication settings, console port, 22 configuration interfaces, 8 connecting network cables, 24 console port, 8, 21, 29 contents of package, 17 cooling requirements, 18 copper cables, 24 ports, 4 crossover cable, 25, 30

D

DB-9 connector, 8 default settings, 12 description of switch, 1 dimensions of switch, 28 downloading software, 8 DTE connection, 21 duplex mode, auto-negotiation of, 10

E ears, mounting, 19 electrical specifications, 28 EMC compliance, 27 environmental requirements, 18 specifications, 27 ESD wrist strap, 20 expansion slots, 6

F fault tolerance port trunking, 11 redundant power, 6 Spanning Tree, 7 features of switch, 2 fiber cables, 24 ports, 26 Flash memory, 8 flow control explained, 33 features, 11 LEDs, 4 frame buffering, 7 frame tagging, 11 front panel components, 4 full duplex LEDs, 4 full-duplex mode, 10

G Gigabit Ethernet cables, 24

H hardware features, 2 hardware tests, 23

data rates, 27 9033630

Index 1

ELS100-48tx2m.book Page 2 Thursday, November 16, 2000 4:59 PM

I

O

IEEE 802.1D, 7 IEEE 802.1p, 11 IEEE 802.1Q, 3, 11 IEEE 802.3, 25 IEEE 802.3x, 11, 33 in-band configuration, 8 in-band connection, 22 indicators, LED, 3 inspecting your shipment, 17 installation in a rack, 19 of optional modules, 20 on table or shelf, 18 requirements, 17

optional modules, 2, 5 out-of-band configuration, 8

L laser safety, iii LED indicators, 3, 4, 10 Link LEDs defined, 4 load balancing, 11 local backbone application, 16 location requirements, 17 long-wavelength fiber interface, 25

M management interfaces, 8 MDI, 25 MDI-X, 25, 29 memory tests, 23 Mgmt LED defined, 4 mirror ports, 9 Mode LEDs defined, 4 modem connection, 22 modules installing, 20 LEDs defined, 4 mounting ears, 19 mounting the switch in a rack, 19 on a table or shelf, 18 multi-mode fiber, 24, 26

N network applications, 14 network management features, 3 network traffic analysis, 9 non-volatile Flash memory, 8 null-modem cable, 21

2 Index

P package contents, 17 password protection, 8 pause frames, 33 physical specifications, 28 pin assignments, 29 ports mirroring, 9 specifications, 29 trunking, 11 types supported, 2 power connector, 6 consumption, 28 source requirements, 17 power cord connecting, 23 set requirements, 30 Power LED defined, 4 powering the switch, 23 power-up diagnostics, 21, 23 priority queuing, 11

R RDP LED defined, 4 rear panel components, 6 redundant power connector, defined, 6 regulatory compliance, 27 reliability features, 3 RJ-45 ports connections, 25 defined, 4 pinouts, 29 RMON, 9 RS-232 port cable connection, 21 out-of-band management, 8 pin assignments, 29 rubber foot pads, 18

S safety compliance, 27 SC ports, 26 screws, mounting, 19

VH-4802

ELS100-48tx2m.book Page 3 Thursday, November 16, 2000 4:59 PM

serial port connecting to, 21 out-of-band management, 8 pin assignments, 29 short-wavelength fiber interface, 24 single-mode fiber, 24, 26 site requirements, 17 slots for modules, 6 SNMP-based network manager, 9 software features, 3 software tests, 23 Spanning Tree Protocol, 7 standards compliance, IEEE, 27 Status LEDs, module, 4 store-and-forward switching, 7 switch description, 1

traffic priority, 11 transmit queues, 33 trunking, 11

T

Web-based network manager, 8 wrist strap, 20

TCP/IP protocol, 8 Telnet, 8, 22 terminal connection, 8, 21 tests, hardware and software, 23 TFTP download, 8

9033520

U unshielded twisted pair (UTP) cables, 24 upgrading software, 8

V ventilation requirements, 18 VLANs, 11 VT100 connection, 8

W

X XMODEM download, 8, 23

Index 3

ELS100-48tx2m.book Page 4 Thursday, November 16, 2000 4:59 PM

4 Index

VH-4802

ELS100-48tx2m.book Page 1 Thursday, November 16, 2000 4:59 PM

ELS100-48tx2m.book Page 2 Thursday, November 16, 2000 4:59 PM

150420-102 R01

View more...